3.3.17. UTOA (Time Of Arrival precise measurements)

There is the possibility to time tag with a high precision (down to few nanoseconds) the first bit of the
synchronization word of a telemetry frame.
The feature is license dependent and is associated with a LBW TMU while being independent from the standard
telemetry flow processing.

3.3.17.1.Prerequisites

The feature applies for telemetry signals with a sub carrier frequency that is an exact integer multiple of the
symbol rate and for which the modulation is BPSK coherent.
Note:
Symbol rate = 2*bitrate in Biphase PCM encoding (BPL/BPM/BPS) while Symbole rate = bitrate in convolutional
encoding.
Bit rate denotes the STI parameter.

3.3.17.2.Supported PCM Codes and Channel Encoding

The following PCM codes and channel encoding are supported:
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
BPL/BPM/BPS + NRZL/NRZM/NRZS + CCSDS Scrambling
BPL + Viterbi / Viterbi inverted + NRZL/NRZM/NRZS + CCSDS Scrambling
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021