Command ranging & telemetry unit
Table of Contents

Advertisement

TCP-IP Interfaces
2.2.2.
All data (TM, TC, Ranging, Monitoring & Control, Logging, etc...) are exchanged between the Signal Processing
Software and the external world (Monitoring & Control Software, COP Software, Control Center clients, etc...)
over a single Ethernet port. The CORTEX CRT Quantum acts as a TCP-IP server for all types of data transfer.
Data are exchanged using the connected-sockets communication protocol.
Some data flows accept multiple clients at a time (monitoring, logging, telemetry, Doppler and spectrum analysis
data), while other flows accept only one client at a time (equipment configuration and reset, satellite
telecommanding).
Each type of transfer flow is allocated a specific port number which the clients use for connecting themselves to
each « service ». Port numbers are listed below (including TCP-IP ports on the optional COP Software package):
CORTEX Monitoring Data (MON)
CORTEX Control Data (CTRL)
CORTEX Reset (RST)
Satellite Telecommand Data (TC)
Simulated Data # 1 (SIM-1)
Simulated Data # 2 (SIM-2)
Ranging Data (RNG)
Ranging Data (MEAS)
Logging Data (LOG)
Spectrum Analysis Data (SPA)
Vector Analysis data (VEC) (see Note 1)
Doppler or Analysis Data (DOP)
Doppler Compensation port (DOPC)
Telemetry Data (TM)
COP Monitoring Data (COP-MON)
COP Control Data (COP-CTRL)
COP Satellite Telecommand Data (COP-
Note 1: "Vector Analysis Data" port available only for SPS 5.30 and higher
A detailed description of this interface (excluding COP ports) is available in Annex 1. The COP software Ethernet
interface is described in RD6.
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Data Flow
TC)
Table 2: Ethernet Ports Addresses
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Port Number
Maximum Number of
3000
3001
3002
3020
3021
3022
3034
3035
3040
3050
4 (total for all IFRs)
3055
8 (total for all TMUs)
3060
8 (total for all IFRs)
3065
3070
24 (total for all TM
3100
3101
3120
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec. 03, 2021Sept.
30, 2021
Connections
8
1
1
1
1
1
1
5
5
1
channels)
4
1
4
Page 42