Integrated Simplified Interconnection Panel; If Carrier Tracking; Nd Order Pll - Safran CORTEX CRT Quantum User Manual

Command ranging & telemetry unit
Table of Contents

Advertisement

IF Carrier Tracking

3.3.3.
Once the carrier frequency is acquired as per previous section, tracking is launched using Phase-Locked Loop
technique.
Cortex CRT XL Quantum uses a 2nd order PLL for carrier tracking.
CRT eXplorer can be configured to 2nd order PLL or 3rd order PLL, using the PLL order registry parameter (see
chapter 4.2.8.2.6). This section describes the performances for tracking only, acquisition performance is not
depending on the loop order and is described in chapter 3.3.2.2.
nd
3.3.3.1. 2
Order PLL
This is the most commonly used PLL. However, for demanding applications, this loop has one drawback:
Example: The C/N0 drives the choice of the Loop Bandwidth. If you want to track a signal with a low C/N0, you
have to choose the narrowest loop bandwidth in order to increase the ratio S/N.
With this hypothesis, reducing the bandwidth implies a lower tracking performance for the Doppler rate.
And finally, the Doppler generates a phase error bias in the loop of
��
is a constant value (approx. 7.05) and it is relative to damping factor (0.7 in case of Cortex).
The total phase error is composed with ϕε and σ which is the standard deviation.
��
with
Signal Noise ratio input (dB.Hz)
��
0
The PLL cannot manage a bias error superior to
Example: With 2BL = 100 Hz, and
�� =
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Expected C/N0 is sizing the loop bandwidth
Loop bandwidth is sizing the Doppler rate
���� ≈
���������������������� <
S
= 40 dB. Hz, the maximum Doppler Rate is :
N
0
��
(������)
��
����
��
− �� √
��
��. ����
��
��
��
��
(
)
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
��
× ����������������������
��
(������)
����
��
�� = √
��
��
��
��
��
, so the maximum admissible Doppler Rate cannot exceed:
2
��
��(������)
��
× (
− ����)
��. ����
��
��
(������)
��
������
=
− ��
��. ����
��
(
��. ����
(
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
Date:
Dec.
03, 2021Sept. 30, 2021
< �������� ����/��
��
)
��
��
����
)
5.17