Safran CORTEX CRT Quantum User Manual page 39

Command ranging & telemetry unit
Table of Contents

Advertisement

1.4.3.3. Monitoring & Control Software Package
The Monitoring & Control software package features monitoring & control of the chassis. It also authorizes a
limited number of functions that are normally dedicated to the Control Center:
Satellite ranging (phase measurement and distance computation),
Satellite telecommanding (limited capabilities),
Telemetry decommutation of a limited set of parameters, with graphical display.
Refer to the Cortex CRT MCS User's Manual for more information.
1.4.3.4. Command Operation Procedure Software Package (COP)
The Command Operation Procedure software allows to receive CCSDS-compliant TC messages at segment or
transfer frame or CLTU level, to check, to reshape and to retransmit them at CLTU level to the Signal Processing
Software package. This optional software also communicates with the Signal Processing software by means of
connected sockets under TCP-IP protocol.
1.4.3.5. SLE Gateway Software Package (CSGW)
The CORTEX SLE Gateway (CSGW), which is fully integrated in the CORTEX Unit, adds SLE services to the
CORTEX system. The following services are supported by the CORTEX SLE Gateway:
SLE Return All Frames (RAF) Service in « online timely », « online complete » and « offline » delivery
modes
SLE Return Channel Frame (RCF) Service in « online timely », « online complete » and « offline » delivery
modes
SLE Forward CLTU Service
CORTEX systems incorporating CSGW act as SLE service provider, and are able to provide the RAF, RCF and
CLTU service to any SLE service user. CSGW support both version 1 and 2 of the SLE services.
1.4.3.6. Password Protection
The following functions are password-protected:
Windows login, Auto login enabled
CORTEX CRT Quantum configuration (refer to the Cortex MCS User's Manual),
Satellite telecommanding from the Monitoring & Control software. Separate passwords for TC database
modification and for TC transmission (refer to the Cortex MCS User's Manual),
Reset of TCP-IP connections from the « TCP-IP » window (refer to the Cortex MCS User's Manual),
Default setting at delivery: cortex (login function). Other functions: no password.
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec. 03, 2021Sept.
30, 2021
Page 14

Advertisement

Table of Contents
loading

Table of Contents

Save PDF