1.6.10. Optional RF Stage
Available only with the option Embedded Frequency Converter
1.6.10.1.Down Convertor Specifications
RF input stages
RF input ports
Input frequency
Input impedance
Output frequency
Output impedance
Return loss
Input level
Maximum total power level
Independent spurious level
Gain
Noise Figure
1.6.10.2.Up Convertor Specifications
RF output stages
RF output ports
Output frequency
Output impedance
Input frequency
Input impedance
Return loss
Mute (ON/OFF)
Output level
Dependent spurious level
Noise density
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
3
1 per input stage (Nominal)
930 to 2400 MHz
50 Ω
70MHz +/- 20MHz
50 Ω
> 15 dB (both Input & Output)
From -20dBm to -105dBm
< -20dBm (or No=-110dBm/Hz for 1GHz noise limited bandwidth)
< -90 dBm signal dependent at max gain in output bandwith
2 modes available:
- Automatic control mode
- Manual mode:
from +10dB to +25dB with Model S105576
from +15dB to +30dB with Model S108984
Typical 12dB @ maximum gain with Model S105576
Typical 10dB @ maximum gain with Model S108984
2
1 per input stage (Nominal)
950 to 2400 MHz
50 Ω
70MHz +/- 20MHz
50 Ω
> 15 dB (both Input & Output)
> 60dB
from +5dBm to -80dBm
< -60 dBc in output bandwidth @Pout > -20dBm
< -112 dBm/Hz
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec. 03, 2021Sept.
30, 2021