Frequency Programming - Safran CORTEX CRT Quantum User Manual

Command ranging & telemetry unit
Table of Contents

Advertisement

Frequency Programming

3.6.2.
For the ESA, INMARSAT and LMCO tone standards, the tone frequencies are fixed. For all other standards, the
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Ranging request
received on port RNG ?
YES
Request accepted
YES
Return positive
primary acknowledgement
message on port RNG
Tables computation
successful ?
YES
Tone transmission/reception
Phase measurement
Ranging sequence
successful ?
YES
Process & time-tag
measurements.
Decrement sequence counter
Return transaction message
on port MEAS
Sequence counter = 0 ?
NO
YES
Return positive
secondary acknowledgement
message on port RNG
Figure 76: Ranging Sequence Flow Chart
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
NO
Return negative
bad syntax or
NO
primary acknowledgement
bad configuration
message on port RNG
Return negative
NO
secondary acknowledgement
message on port RNG
Return negative
NO
secondary acknowledgement
open loop, H/W failure...
message on port RNG
NO
Continuous mode
requested ?
Major tone alone
Phase measurement
Return transaction
message on port MEAS
YES
Stop Ranging command
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021
YES
Range update
Time-tagging
NO
received ?
Page 151

Advertisement

Table of Contents
loading

Table of Contents