4.2.7.5.5. Extended Idle Patterns (1 to 255)

To define the extended idle patterns.
Registry path:
Keyword:
Default setting at delivery:
Configure the value of the extended Idle pattern, up to 8192 bits. The index of the pattern is selected owing to the
8 MS bits of the Idle pattern configuration parameter. The extended idle pattern is entered as a series of
hexadecimal values, using the Binary Value feature of the Registry Editor. When the length of the extended idle
pattern is not a multiple of a byte, the value must be left-justified and the last byte is padded with zeros.

4.2.7.5.6. Extended Preamble Patterns (1 to 255)

To define the extended preamble patterns.
Registry path:
Keyword:
Default setting at delivery:
Configure the value of the extended Preamble pattern, up to 8192 bits. The index of the pattern (x) is selected
owing to the 8 MS bits of the Preamble pattern configuration parameter. The extended preamble pattern is
entered as a series of hexadecimal values, using the Binary Value feature of the Registry Editor. When the
length of the extended preamble pattern is not a multiple of a byte, the value must be left-justified and the last
byte is padded with zeros.

4.2.7.5.7. Always Idle

To define the minimum idle length (in bits) inserted between two clear TC.
Registry path:
Keyword:
Default setting at delivery:
If this key is present, then an IDLE of the length defined by this key will be inserted systematically between two
clear TC.

4.2.7.5.8. Enable primary acknowledgement

To enable primary acknowledgement:
Registry path:
Keyword:
Default setting at delivery:
Enter 1 to enable primary acknowledgement.
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tcu
ExtIdlex (x = 1 to 255)
0
HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tcu
ValPreax (x = 1 to 255)
0
HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tcu
AlwaysIdle
0 (Idle length in bits)
HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tcu
PrimaryAck
0
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021
Page 246