Configuration Of The Deaf Algorithm - Safran CORTEX CRT Quantum User Manual

Command ranging & telemetry unit
Table of Contents

Advertisement

3.3.15.2.1.Configuration of the DEAF Algorithm

Several parameters are available for configuring the DEAF algorithm. They can be found in the STI 100013_TTC
(TMU monitoring and control table). They are the following:
The filter to which the algorithm converges can be saved in a set of custom filters. This feature avoids waiting for
the algorithm to converge at each signal reacquisition. In fact, if the IFR is restarted, or if the PLL unlocks, the
DEAF algorithm stops and the matched filter is reinitialized.
The filter with which the algorithm is initialized can be chosen among the ones listed in the TMU table. They are
Integrate and Dump filter, Raised cosine filter, Root raised cosine filter, or a custom filter.
Custom filters are saved in a folder specific to each TMU. The path to this folder is chosen in the registry key
HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefaultN\Preferences\TmuX\DEAFFirPath
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
Figure 48: Constellation of the received signal with DEAF activated
The DEAF algorithm can be turned on and off. Once the algorithm is turned on, it can be
turned off without restarting the signal acquisition. That means that when the user is
satisfied with the solution achieved, the algorithm can be stopped.
The speed of the algorithm can be set to fast or slow.
The impulse response of the adaptive filter can be forced to be symmetric.
The impulse response of the adaptive filter can be set to real or complex.