Ranging Transaction Messages

3.6.6.

3.6.6.1. Range Measurement

The ranging transaction response message for a range measurement request contains:
Two-way « Distance » values, in nanoseconds (after ambiguity solving. Not significant for the
INMARSAT and LMCO standards,
The ambiguity solving quality factor (not significant for the INMARSAT and LMCO standards).
Then, for each tone and only in case of request for phase and time measurements:
Major tone phase-shift values (∆Φ
Correction »,
Minor tone phase-shift values (∆Φ
CORTEX CRT Quantum returns average phase-shift values, including Doppler compensation but
excluding « Spectrum Correction » and « Board Correction ». Not significant for the ESA code
standard.
Correction for spectrum offsets and on-board phase-delay (∆Φ
tone.
All phase values are expressed in degrees, with a resolution of 360°/2

3.6.6.2. Calibration Measurement

The ranging termination message for a calibration measurement request contains:
Two-way « Distance » values, in nanoseconds (after ambiguity solving. Not significant for the
INMARSAT and LMCO standards),
The ambiguity solving quality factor (not significant for the INMARSAT and LMCO standards),
Then, for each tone and only in case of request for phase and time measurements:
Major tone phase-shift values (∆Φ
Correction »,
Minor tone phase-shift values (∆Φ
CRT Quantum returns average phase-shift values, including Doppler compensation but excluding «
Spectrum Correction » and « Ground Correction ». Not significant for the ESA code standard.
Correction for spectrum offsets and ground phase-delay (∆Φ
tone.
All phase values are expressed in degrees, with a resolution of 360°/2
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
������
������
������
������
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
), excluding « Spectrum Correction » and « Board
). For the ESA, ESA-like and USB tone standards, the
16
≈ 0.0055°.
), excluding « Spectrum Correction » and « Ground
). For the ESA, ESA-like and USB standards, the CORTEX
����������������
16
≈ 0.0055°.
Safran Data Systems
.