I/O Connectors description
2.3.2.
2.3.2.1. External interconnection panel
The connectors are described based on the groups of functions highlighted by lines and a general label on the interconnection panels.
For any signal, all characteristics and labels are identical whatever chassis is supplied.
C
C
ONNECTOR
ONNECTOR
T
P
YPE
ANEL
L
ABEL
BNC Female
NOMINAL IF
1
BNC Female
ALTERNATE IF
1
BNC Female
NOMINAL IF
2
BNC Female
ALTERNATE IF
2
BNC Female
VIDEO IN
1
BNC Female
VIDEO IN
2
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
C
MSP
ABLE
MODULE
S
LEEVE
CONNECTOR
L
ABEL
LABEL
UPLINK
UL NOM IF1
IF out
NOM 1
UL ALT IF1
IF out
ALT 1
UL NOM IF2
IF out
NOM 2
UL ALT IF2
IF out
ALT 2
UL V
IN1
Note 1
IDEO
Note 1
UL V
IN2
IDEO
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
SIGNAL
IFM-1 Nominal IF output port
IFM-1 Alternate IF output port
IFM-2 Nominal IF output port
IFM-2 Alternate IF output port
Auxiliary video input to IFM-1
(analog signal)
Auxiliary video input to IFM-2
(analog signal)
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
Date:
30, 2021
E
LECTRICAL CHARACTERISTICS
50-90 MHz (-3 dB bandwidth)
0 to - 80 dBm, 50 
DC-90 MHz (-3 dB bandwidth)
- 20 dBm, 50 
50-90 MHz (-3 dB bandwidth)
0 to - 80 dBm, 50 
DC-90 MHz (-3 dB bandwidth)
- 20 dBm, 50 
100 Hz - 2 MHz
2 Vpp - 50
100 Hz - 2 MHz
2 Vpp - 50
5.17
Dec. 03, 2021Sept.