5.2.2.3. What to do in case of Temperature Alarm

In case of temperature alarm
Immediately shutdown and switch off the chassis to avoid any damage to the hardware.
Verify that the air exhaust system of the housing rack works properly,
Verify that the air intake and exhaust grids are clear. Important: a free rack space must be provided above
and below the chassis, except for the 2U chassis IS00452
Check the cooling fans on both sides of the chassis, at the rear panel of the chassis (power supply
module) and on CPU processors.
Return the chassis to SAFRAN DATA SYSTEMS or its maintenance representative if the problem cannot
be fixed on site.

PC Workstation Maintenance

5.2.3.
Refer to Annex 4 for detailed instructions on how to change:
The power supply module
The fan units
The disk drives: floppy, hard disk and CD ROM
The display assembly
The keyboard.
5.3. Software Upgrade & Installation
The CORTEX CRT software comes under the form of Compact Disks (CD ROM):
 Windows Operating System: to re-install the operating system after a disk failure, use SAFRAN DATA
SYSTEMS DVD-ROM Windows Restore for CORTEX.
 CORTEX CRT software: to re-install or upgrade the CORTEX CRT software, use SAFRAN DATA
SYSTEMS CD ROM reference CORTEX CRT <Customer_name> 100xxx <Project_name>. The CD
includes the Cortex CRT application software, Cortex CRT Quantum board driver, and the user
documentation.
Strictly follow the install procedure described at the back of the CD ROMs.
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021
Page 261

Advertisement

Table of Contents
loading

Table of Contents