Safran CORTEX CRT Quantum User Manual page 269

Command ranging & telemetry unit
Table of Contents

Advertisement

Assuming that these parameters are: 500 kHz (tone frequency), 1 (no under-sampling), 4.3 s (integration time),
10 measurements on the tone and 1 Hz (loop bandwidth), the sequence duration is (the time to compute the tone
definition tables is not included):
Pre-transmission of the tone
Integration time
10 measurements on the tone (0.25 x 9) + Ts
Total sequence duration
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
: 3.01 s
:
4.30 s
: 7.26 s
: 14.57 seconds
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021
Page 189