Table 22: Cartesian - To -Polars - Safran CORTEX CRT Quantum User Manual

Command ranging & telemetry unit
Table of Contents

Advertisement

We notice that:
In the first term, the demodulated output is amplified when the discriminator delay is increased or when the
Cartesian-to-polar sampling frequency Fs is decreased,
The sinc term filters the output with a bandwidth which is increased when the Cartesian-to-polar sampling
frequency Fs is increased or when the discriminator delay is decreased.
There are the values of the Cartesian-to-polar sampling frequency Fs corresponding to the different Pre-
Detection filters:
Pre-Detection Filter
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
10 MHz
5 MHz
3 MHz
1.5 MHz
1 MHz
500 kHz
300 kHz
150 kHz
5 to 100 kHz
Table 22: Cartesian-to-Polar Sampling Frequencies
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
Cartesian-to-Polar sampling frequency
31.25 Msps
31.25 Msps
25 Msps
25 Msps
25 Msps
5 Msps
2.5 Msps
2.5 Msps
312.5 ksps
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021
Page 31

Advertisement

Table of Contents
loading