Safran CORTEX CRT Quantum User Manual page 45

Command ranging & telemetry unit
Table of Contents

Advertisement

IF Reception
1.6.1.
1.6.1.1. Analog Reception
1.6.1.1.1. IF Stages
IF input stages
IF input ports
Input bandwidth
Input impedance
VSWR
Isolation between channels
Aliasing rejection
Maximum noise level
(or No = - 96 dBm/Hz for 40 MHz noise bandwidth)
AGC range (CRT XL Quantum)
AGC range (CRT eXplorer)
AGC time constant
AGC mode
1.6.1.1.2. Auxiliary Inputs
Two Auxiliary input ports allow receiving baseband or IF signals for test purposes (example: TC demodulation at
IF):
Input ports
Input signal
Input bandwidth
Input signal level
AGC
Input impedance
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
3
2 per input stage (Nominal & Alternate)
50 to 90 MHz (- 3 dB bandwidth)
50 Ω
≤ 1.25
≥ 80 dB
≥ 80 dB
- 20 dBm
- 15 to -105 dBm
- 15 to -120 dBm
0.1, 1, 10, 100 or 1,000 ms
Analog AGC : Non coherent
Digital AGC : Non coherent before carrier acquisition
then coherent (for PM and direct PCM, in a few Hz)
2
Baseband or IF signal
At baseband
At IF
At baseband
At IF
No
50 Ω
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Ref.
Is.Rev.
Date:
30, 2021
: DC to 20 MHz
: 0 to 90 MHz
: 0.1 to 0.5 Vpp
: 0 to - 20 dBm
DTU 100042
5.17
Dec. 03, 2021Sept.
Page 20