Configure Additional Status - Safran CORTEX CRT Quantum User Manual

Command ranging & telemetry unit
Table of Contents

Advertisement

4.1.5.4.4. Configure Additional Status

The front panel display allows the user to add up to 20 statuses in the MISC submenu. To select the additional
status, the user shall update the file "ipc_ihm.ini" that can be found in the folder C:\Program Files\ZDS\LCD\
In this file, after the [MISC] section, the user shall add a line for each additional status that is expected to be
displayed, according to the following layout: "StatusName"=("TableNumber","OffsetValue")"Type"
Where "TableNumber" is the STI100013 monitoring table from whom the status is included, "OffsetValue" is the
status offset in this table, and "Type" is the selected option for display.
Example:
[MISC]
Bitrate=(0x1060,1)FLOAT
File Number=(0x1020,6)INT
Alarm Misc=(0x1001,41)HEX
FrameSync=(0x1060,49)LIST:Search,Check,Locked,Flywheel
The first line allows to monitor the TTC Telemetry Unit A (TableNumber=0x1060) BitRate (OffsetValue =1) as a
float value. The second line allows to monitor the TTC Telemetry Simulator #1 (TableNumber=0x1020) file
number (OffsetValue =6) as a integer value. The third line allows to monitor the TTC Global Monitoring
(TableNumber=0x1001) alarm status (OffsetValue =41) as a hexadecimal value. The last line allows to monitor
the TTC Telemetry Unit A (TableNumber=0x1060) frame synchronizer status (OffsetValue =49) with the
transcription of the integer value into a string. In this example, the following transcription is applied:
For a "List" option, each string is limited to 16 characters. All values from 0 to the maximum value shall have a
transcription, as detailed with the example below.
Example: Status 46 in TT&C IF Receiver table:
46
Doppler Storage=(0x1040,46)LIST:Storage Off,Storage ON, N/A,N/A,Directory Error
Values 2 and 3 are not available, but needs to be transcripted by a string to fill the gap. In this example, these
values are transcripted with "N/A" string.
© Safran Data Systems
COMMAND RANGING & TELEMETRY UNIT CORTEX
CRT QUANTUM USER'S MANUAL
0 -> Search
1 -> Check
2 -> Locked
3 -> Flywheel
Current Doppler
Storage status (CRT-
Integer
Q version E5R19 and
This document is the property of
It cannot be duplicated or distributed without expressed written consent.
4: Create File or Directory error
higher)
Safran Data Systems
.
Ref.
DTU 100042
Is.Rev.
5.17
Date:
Dec.
03, 2021Sept. 30, 2021
0: Storage Off
1: Storage On
Page 226

Advertisement

Table of Contents
loading

Table of Contents