Spindle Synchronization Control Ll; Function And Purpose; Detailed Description - Mitsubishi Electric M800VW Series Programming Manual

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
13 Spindle Control

13.11 Spindle Synchronization Control ll

13.11 Spindle Synchronization Control ll

13.11.1 Function and Purpose

For spindle synchronization function ll, selection of the synchronized spindle and synchronization start, etc., are all designated
from the PLC. Refer to the instruction manual issued by the machine tool builder for details.
While this function is running, other spindle synchronization function (Spindle synchronization control I, spindle
synchronization control II, tool spindle synchronization IA, tool spindle synchronization IB, tool spindle synchronization II, or
spindle superimposition control) cannot be commanded. Similarly, while other spindle synchronization function is running,
spindle synchronization control II cannot be commanded. An operation error (M01 1005) occurs then.

13.11.2 Detailed Description

 Reference spindle and synchronized spindle selection
Select the reference spindle and synchronized spindle for synchronous control from the PLC.
Device No.
Signal name
R7016
Reference spindle selec-
tion
R7017
Synchronized spindle se-
lection
Abbrev.
-
Select a serially connected spindle to be controlled as the refer-
ence spindle.
(0: 1st spindle)
1: 1st spindle
2: 2nd spindle
3: 3rd spindle
4: 4th spindle
5: 5th spindle
6: 6th spindle
7: 7th spindle
8: 8th spindle
<Note>
 Spindle synchronization will not take place if a spindle not con-
nected in serial is selected.
 If "0" is designated, the 1st spindle will be controlled as the ref-
erence spindle.
-
Select a serially connected spindle to be controlled as the syn-
chronized spindle.
(0: 2nd spindle)
1: 1st spindle
2: 2nd spindle
3: 3rd spindle
4: 4th spindle
5: 5th spindle
6: 6th spindle
7: 7th spindle
8: 8th spindle
<Note>
 Spindle synchronization will not take place if a spindle not con-
nected in serial is selected or if the same spindle as the refer-
ence spindle is selected.
 If "0" is designated, the 2nd spindle will be controlled as the syn-
chronized spindle.