M800V/M80V Series PLC Programming Manual (1/2)
4 Explanation of Devices
4.4 Detailed Explanation of Devices
4.4.7 Timer T
The 100 ms timer and 10 ms timer are available for this count-up type timer.
The 100 ms timer and 10 ms timer are differentiated by the instructions used. Refer to "7.3 Output Instructions" for details.
100 ms timer T
When the input conditions are set, the count starts. When the set value is counted, that timer contact will turn ON.
If the input conditions are turned OFF, the 100 ms timer count value will be set to 0, and the contact will turn OFF.
X5
Input
conditions
The value is set with a decimal, and can be designated from 1 to 32767 (0.1 to 3276.7 (s)). The data register D or file
register R data can be used as the setting value.
10 ms timer T
When the input conditions are set, the count starts. When the set value is counted, that timer contact will turn ON.
If the input conditions are turned OFF, the 10 ms timer count value will be set to 0, and the contact will turn OFF
X5
Input
conditions
The value is set with a decimal, and can be designated from 1 to 32767 (0.01 to 327.67 (s)). The data register D or file
register R data can be used as the setting value.
With the device T, the contact/coil is handled as bit device, and the current value is handled as word device.
In the function instructions described after, the word device T indicates the current value even if there is no description about
it.
IB-1501667-B
X5
K50
T193
T193 coil
T193 contact
100 ms timer
Display for 10ms timer instruction
X5
H K500
T1
T1 coil
T1 contact
10 ms timer
ON
OFF
ON
OFF
5 seconds
OFF
ON
ON
OFF
OFF
ON
5 seconds
OFF
ON
40