M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.37 Direct Screen Selection
(4) Designate the screen No. or window No. of each screen, using the offset No. of the module to display + screen (window)
No.
Do not designate a window No. for screen No. Conversely, do not designate a screen No. for a window No.
The offset No. is necessary to designate the screen (window) No. even if they are in the same project.
Screen (window) No. = offset of the module + screen (window) No.
[MODULE]
NUM=1
MODULE_NAME01=CUSTOM_A.DLL
PAGE_OFFSET01=6500
Target No.
Function No.
Main menu No.
Sub menu No.
Menu No.
Screen No.
Window No.
(*1) The No. range for the Monitor screen, Setup screen and Edit screen is 0 and 8000 to 9999.

14.37.2 Timing Chart

The timing chart of the selection requirement/completion data is shown below.
PLC
NC
Before transition
Screen
 The screen selection completion (R356 = 4) is set after the screen transition.
 If the screen transition cannot be performed, the selection completion data (R356) may remain to be "1". Therefore, if there
is no change over 2 seconds after the screen selection request (R356) is set to "1", set the signal to "0" with the PLC.
When the 2nd window of CUSTOM_A.DLL is designated, the formula will
be as below. Set 6502 to the register.
6500 + 2 = 6502
No. range
1 to 5, 9, 10, 13 and 14
0 to 30
0 to 70
0 to 10
0 and 6000 to 7999
0 and 6000 to 9999 (*1)
0 → 1
1 → 4
4 → 0
After transition
879