Mitsubishi Electric M800VW Series Programming Manual page 626

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.10 Arbitrary Reverse Run
Valid G code
Only the specified G codes allow the reverse run. Valid G codes are shown below.
The G codes out of the list are invalid. Do not execute the reverse run to the invalid G codes.
G code group
Valid/Invalid
00
Valid
01
Valid
02
Valid
03
Valid
04
Invalid
05
Invalid
06
Valid
07
Invalid
08
Invalid
09
Invalid
10
Invalid
11
Valid
12
Valid
13
Invalid
14
Valid
15
Invalid
16
Invalid
17
Invalid
18
Invalid
19
Valid
21
Invalid
(*1) The figure rotation cannot be executed with M98(G22).
(*2) In G95 modal, the reverse/forward run is executed with "the last commanded speed * spindle speed (mm/rev)"
 Insert G04; before the G code with "*".
 The G codes in "( )" are used for M2 format.
Valid G code (default G code if invalid)
G04, G52*, G53*, G60, G65, G92*, G92.1*, M96(ION), M97(I0F),
M98(G22) (*1), M99* (G23*)
GO0, G01, G02, G03
G17
G90, G91
G23(G23.1)
G94, G95 (*2) (According to the modal when the reverse run information is started to
be stored.)
G20, G21
G40
G49
G80
G98
G50, G51
G54, G55, G56, G57, G58, G59, G54.1
G64
G66, G66.1, G67
G40.1(G15)
G69(G69.1)
G97
G15
G50.1, G51.1, (G62)
G07.1 OFF, G13.1(G11)
605
IB-1501668-B