Mitsubishi Electric M800VW Series Programming Manual page 931

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
16 External PLC link
16.1 CC-Link
Item
Version 1.10 compatible CC-Link dedicated cable (terminal resistor of 110Ω used)
Transmission
speed
156 kbps
625 kbps
Maximum overall cable
2.5 Mbps
distance and station to
5 Mbps
station cable length
10 Mbps
Station to station cable length is 20 cm or longer regardless of the transmission speed.
<Note>
 When CC-Link Ver.1.00 compliant cables are mixed, the cable length between stations and the maximum total
length of the cable should follow the specifications for CC-Link Ver.1.00.
Version 1.10 compatible CC-Link dedicated cable
(3-core twisted pair cable with shield)
Connection cable
<Note>
 This can be used with the cables made by different manufacturers as long as they are Ver.1.10 compliant ca-
bles.
 Automatic return function
RAS function
 Slave station cut-off function
(*1)
 Error detection by the link special relay/register
(*1) "RAS" stands for "Reliability", "Availability" and "Serviceability".
IB-1501668-B
CC-Link master/local module
Maximum overall cable
distance
1200 m
900 m
400 m
160 m
100 m
910