Spindle Parameters; Spindle Base Specifications Parameters - Mitsubishi Electric MELDAS C6 Parameter Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

8. Spindle Parameters

8.1 Spindle Base Specifications Parameters

For parameters indicated with a (PR) in the table, turn the NC power OFF after setting. The setting is
validated after the power is turned ON again.
No.
Items
3001
slimit 1
Limit rotation
speed
3002
2
3003
3
3004
4
3005
smax 1
Maximum
rotation speed
3006
2
3007
3
3008
4
3009
ssift
1
Shift rotation
speed
3010
2
3011
3
3012
4
3013
stap 1
Tap rotation
speed
3014
2
3015
3
3016
4
3017
stapt 1
Tap time
constant
3018
2
3019
3
3020
4
8. Spindle Parameters
8.1 Spindle Base Specifications Parameters
Set spindle rotation speed for maximum motor
rotation speed with gears 00, 01, 10, 11.
(Set the spindle rotation speed for the S analog
output 10V.)
Set maximum spindle speed with gears 00, 01,
10, 11.
Set the value that is equal to or larger than "slimit"
value.
By comparing the S command value of gear 1 to
4, a spindle gear shift command will be output
automatically.
Set spindle rotation speed for gear shifting with
gears 00, 01, 10, 11.
(Note) Setting too large value may cause a gear
nicks when changing gears.
Set maximum spindle rotation speed during tap
cycle with gears 00, 01, 10, 11.
Set time constants for constant inclination
synchronized tapping for gears 00, 01, 10, 11
(linear acceleration/deceleration pattern).
174
Get other manuals https://www.bkmanuals.com
Details
Setting range
(Unit)
0 to 99999 (r/min)
0 to 32767 (r/min)
0 to 99999 (r/min)
1 to 5000 (ms)