M800V/M80V Series PLC Programming Manual (1/2)
7 Basic Instructions
7.2 Connection Instructions
Arithmetic errors
There are no arithmetic errors with ANB or ORB instructions.
Program example
A program using ANB and ORB instructions
X0
0
X2
X4
9
[Ladder mode]
M0
X1
X3
X5
END
127
[List mode]
Steps
Inst.
Device
0
LD
X0
1
OR
X2
2
LD
X1
3
OR
X3
4
ANB
5
LD
X4
6
AND
X5
7
ORB
8
OUT
M0
9
END