Mitsubishi Electric M800VW Series Programming Manual page 619

Plc programming
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Programming Manual (2/2)
14 PLC Help Function
14.8 High-Speed Simple Program Check
Miscellaneous command output function
Output of miscellaneous commands during the high-speed simple program check can be enabled/disabled with parameters.
Enabling/disabling of the miscellaneous command output is set when the related parameters and PLC signals satisfy the
conditions listed in the following table.
Miscellaneous function lock (AFL) disabled
#1278 ext 14/bit 5
1
M code configured to "#1451 M[M031-000] (SM-
LK)" through "#1466 M[M511-480] (SMLK)": M
0
output enabled
Otherwise: M output disabled
#1405
M_mode (SMLK)
M code not configured to "#1451 M[M031-000]
(SMLK)" through "#1466 M[M511-480] (SMLK)":
1
M output enabled
Otherwise: M output disabled
0
S output disabled
#1406
S_mode (SMLK)
1
S output enabled
0
T output disabled
#1407
T_mode (SMLK)
1
T output enabled
0
M2 (B) output disabled
#1408
M2_mode (SMLK)
1
M2 (B) output enabled
Note
(1) When miscellaneous function output is enabled while the high-speed simple program check is in operation, the program
issues a strobe for all enabled signals and waits for completion from the PLC.
(2) The miscellaneous command code is also output during the high-speed simple program check by enabling miscellaneous
function output, and so miscellaneous functions operate by the reception of signals from ladders. Be aware of the config-
uration details of miscellaneous function codes enabled for output.
(3) When "#1405 M_mode (SMLK)" is set to "1", be aware of the configuration details as M codes larger than M511 will be
output.
(4) Miscellaneous functions will not be output regardless of the setting of "#1278 ext 14/bit 5" when the miscellaneous func-
tion lock (AFL) is enabled.
(5) The miscellaneous function command high-speed output option is selected when the miscellaneous command code con-
figured with miscellaneous function output enabled matches the miscellaneous command code configured to the miscel-
laneous function command high-speed output parameter.
(6) When miscellaneous command output is disabled, the miscellaneous command block is not included in the estimated
processing time.
IB-1501668-B
0
Miscellaneous function
output disabled
598
Miscellaneous function lock (AFL) en-
abled
#1278 ext 14/bit 5
1
0
Miscellaneous function output dis-
abled

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents