11 Parameters

11.3 Other Parameters

11.3 Other Parameters

11.3.1 PLC Startup Condition Switchover

Parameter "#11004 PLCautorun enable" allows PLC to startup at NC startup even if no setting display unit is used.
For safety, use this function only for the machine with no NC screen displayed by HMI.
 Base common parameter
# No.
Item
11004
PLC automatic
PLCautorun enable
(PR)
startup valid
 Precautions
Parameter "#11004 PLCautorun enable" is the parameter prepared on the assumption that the setting and display unit is not
used.
For the machine with NC screen displayed, to ensure your safety, always set "#11004 PLCautorun enable" to "0" and start
PLC after NC screen startup.
When PLC automatic startup is validated without confirming the pre-operation status on the NC screen, unexpected incident
may occur.
IB-1501667-B
Details
Switch starting condition of the PLC.
0: Start PLC after NC screen startup
1: Start PLC at NC startup
462
Setting
Standard
range
value
0, 1
0