M800V/M80V Series PLC Programming Manual (1/2)
4 Explanation of Devices
4.3 Device Range Setting at Multi-project

4.3.1 Common Device Among Projects

Devices written below are the ones that are common among projects.
The number of points below can be used from each project without being affected by the number of projects.
Device
X
Y
F
R
ZR
Note
(1) The above devices will not have the independent access for each project.
Therefore, it will be affected by the access from multiple projects.
[Write value to R8300 from Project 1 & 2]
Project 1
0
Project 2
0
When the multiple projects use a device of the same device number, the output to the device of the project which was
executed last will be valid. Consider the execution order of projects thoroughly.
IB-1501667-B
Device range
X0 to X1FFF
Y0 to Y1FFF
F0 to F2047
R0 to R32767
32768 points
ZR0 to ZR13311
13312 points
MOV K100 R8300
MOV K0 R8300
8192 points
8192 points
2048 points
Storing data
R8300
value
Execute PRJ1
100
Execute PRJ2
0
Execute PRJ1
100
30