(2) MECHATROLINK-II I/O Monitor (IO_MON) Field
If the Active Mode ON Signal is allocated to CN1 in a SERVOPACK with MECHATROLINK-II Communi-
cations Reference, the operating state of Active Mode Function can be monitored in the I/O monitor field. The
allocation of monitor information and information on the I/O monitor (IO_MON) field are given below. For
details on allocation of the Active Mode ON Signal, refer to (1) Active Mode ON Signal.
Monitor Information Allocations
Parameter
No.
Input Signal Monitor
Pn81E
Selection
Details
IO12 Signal Mapping
0 to 7
Pn81E.0
8
9
A
IO13 Signal Mapping
Pn81E.1
0 to A
IO14 Signal Mapping
Pn81E.2
0 to A
IO15 Signal Mapping
Pn81E.3
0 to A
Monitor Information
Bit
Name
d12
IO12
d13
IO13
d14
IO14
d15
IO15
Note: For details on MECHATROLINK-II communications, refer to the
Command (No.: SIEP S800000 54).
(3) MECHATROLINK-III I/O Signal Monitor (SVCMD_IO) Field
If the Active Mode ON Signal is allocated to CN1 in a SERVOPACK with MECHATROLINK-III communi-
cations, the operating state of the Active Mode Function can be monitored in IO1 to IO8 in the I/O signal
monitor (SVCMD_IO) field. The following tables provide information on the allocation of the output signal
monitor and the I/O signal monitor (SVCMD_IO) field. For details on allocation of the Active Mode ON Sig-
nal, refer to (1) Active Mode ON Signal.
Setting
Name
Range
–
Same as the parameters of M-II communications reference model.
Monitors the CN1-1/(2) output terminal.
Monitors the CN1-23/(24) output terminal.
Monitors the CN1-25/(26) output terminal.
Same as the IO12 signal mapping
Same as the IO12 signal mapping
Same as the IO12 signal mapping
Description
I/O signal of CN1 that is set in Pn81E.0
I/O signal of CN1 that is set in Pn81E.1
I/O signal of CN1 that is set in Pn81E.2
I/O signal of CN1 that is set in Pn81E.3
Factory
Units
Setting
–
0000
I/O Signal Monitor
0 = OFF, 1 = ON
0 = OFF, 1 = ON
0 = OFF, 1 = ON
0 = OFF, 1 = ON
-V Series User's Manual MECHATROLINK-II
10.2 Basic Functions
When Enabled
Immediately
Display