(2) Operating from the Panel Operator
The procedure for operating from the panel operator is shown below.
Step Display After Operation
1
2
3
4
5
6
7
8
Note: If the following events occur while a parameter is being edited, the utility function is ended forcibly before the
results are confirmed, and the status is displayed in the panel. If this occurs, execute the utility function again.
• If an alarm occurs while the utility function is being executed from the panel operator
• If a digital operator is connected to the SERVOPACK
8.3 Safety-related Module Parameter Setting (Fn041)
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or DOWN Key to display "Fn041."
MODE/SET
DATA/
Press the DATA/SHIFT Key for at least one second to
display the parameter number selection screen.
MODE/SET
DATA/
Press the DATA/SHIFT Key, and UP or DOWN Key to
set the parameter number.
Note: If the DATA/SHIFT Key is pressed for at least one
second, the display returns to the parameter number
MODE/SET
DATA/
selection screen.
Press the MODE/SET Key to display the set value of the
selected parameter number.
MODE/SET
DATA/
Press the DATA/SHIFT Key, and UP or DOWN Key to
set the parameter value.
Note 1. When the "P.0000" (edit screen) has not been set
MODE/SET
DATA/
2. If the DATA/SHIFT Key is pressed for at least
Press the MODE/SET Key to save the set value.
When the set value has been saved, "donE" flashes for
approx. one second and the parameter value is displayed.
Note 1. When the "P.0000" (edit screen) has not been set
MODE/SET
DATA/
2. If an attempt to save the set value fails: 
Press the DATA/SHIFT Key for at least one second to
return to the utility function selection screen.
MODE/SET
DATA/
Operation
with the Safety Module Access Mode Setting
(Fn040): 
"no-oP" flashes for approx. one second. Set the
"P.0000" (edit screen) with Fn040.
one second, the display returns to step 4.
with the Safety Module Access Mode Setting
(Fn040): 
"no-oP" flashes for approx. one second. Set the
"P.0000" (edit screen) with Fn040.
"Error" flashes for approx. one second, and the
display returns to step 6. Try to make the set-
tings again.