YASKAWA E-V Series User Manual page 130

Ac servo drives
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

8 Utility Functions
8.2.2 Operation Procedures
(2) Operating from the Panel Operator
The procedure for operating from the panel operator is shown below.
Step Display After Operation
1
2
3
4
5
6
Note: If the following events occur while the access mode is being changed, the utility function is ended forcibly before
the results are confirmed, and the status is displayed in the panel. If this occurs, execute the utility function again.
• If an alarm occurs while the utility function is being executed from the panel operator
• If a digital operator is connected to the SERVOPACK
8-4
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or DOWN Key to display "Fn040."
MODE/SET
DATA/
Press the DATA/SHIFT Key for at least one second to
display "P.0001."
Note: If an error occurs: 
MODE/SET
DATA/
Press the DOWN Key to display "P.0000."
Note: If the DATA/SHIFT Key is pressed for at least one
MODE/SET
DATA/
Press the MODE/SET Key to save the set value. When the
set value has been saved, "donE" flashes for approx. one
second and then "P.0000" is displayed again.
Note: • If an attempt to save the set value fails: 
MODE/SET
DATA/
Press the DATA/SHIFT Key for at least one second to
return to the utility function selection screen.
MODE/SET
DATA/
Operation
"no-oP" flashes for approx. one second, after which
"Fn040" is displayed again.
second, "Fn040" is displayed again.
"Error" flashes for approx. one second and then
"P.0000" is displayed again. Try to save the set
value again.
• If an error occurs: 
"no-oP" flashes for approx. one second, and
"P.0000" is displayed again.