3 SERVOPACK Installation
3.3.4 SGDV-EA (Command Option Attachable Type)
Attachment Methods of Ferrite Cores
Recommended Ferrite Core
Ferrite Core Model
Recommended Noise Filter and Surge Absorber
For more information on recommended noise filters and surge absorbers, refer to
(KAEP S800000 42).
Fixing the Cable
Fix and ground the cable shield using a piece of conductive metal.
• Example of Cable Clamp
Shield Box
A shield box, which is a closed metallic enclosure, is effective as reinforced shielding against electromagnetic
interference (EMI) from SERVOPACKs. The structure of the box should allow the main body, door, and cool-
ing unit to be attached to the ground. The box opening should be as small as possible.
<Note>
Do not connect the digital operator and the analog monitor cable to the SERVOPACK during operations.
Connect them only when the machinery is stopped during maintenance.
3-36
One turn
Cable
Ferrite core
ESD-SR-250
NEC TOKIN Corp.
Host controller side
Ground plate
Two turn
Cable
Ferrite core
Manufacturer
Cable
Shield (cable sheath stripped)
Fix and ground the cable shield
using a piece of conductive metal.
Cable
clamp
Remove paint on mounting surface.