[Parameter error list (Obj. 2A45h)]

[Parameter error list (Obj. 2A45h: 00h)]

Data Type
Access
U8
RO
Description
The total number of Sub Index (= 254) is returned.
[Parameter error list 1 (Obj. 2A45h: 01h)] - [Parameter error list
254 (Obj. 2A45h: FEh)]
Data Type
Access
U16
RO
Description
During [AL. 037 Parameter error] occurrence, a list of servo parameter numbers that caused the alarm is returned.
The descriptions of [Parameter error list 1 (Obj. 2A45h: 01h)] to [Parameter error list 254 (Obj. 2A45h: FEh)] are as follows.
If [Pr. PC01] is an error factor, "0201h" is returned.
When no error has occurred, "0000h" is returned.
Bit
Description
0 to 7
Servo parameter number
8 to 15
Servo parameter group number
00h: [Pr. PA _ _ ]
01h: [Pr. PB _ _ ]
02h: [Pr. PC _ _ ]
03h: [Pr. PD _ _ ]
04h: [Pr. PE _ _ ]
05h: [Pr. PF _ _ ]
0Bh: [Pr. PL _ _ ]
0Ch: [Pr. PT _ _ ]
0Eh: [Pr. PN _ _ ]
6.7

[Reset alarm (Obj. 2A46h)]

[Reset alarm (Obj. 2A46h: 00h)]

Data Type
Access
U16
RW
Description
The alarm that has occurred in the servo amplifier is cleared.
Writing "1EA5h" resets an alarm. Any value other than "1EA5h" is invalid.
When read is performed, "0000h" is returned.
6 Alarm Objects
38
6.6 [Parameter error list (Obj. 2A45h)]
Mapping
Default
Impossible
254
Mapping
Default
Impossible
0000h
Mapping
Default
Impossible
0000h
Range
Units
254 (fixed)
Range
Units
0000h to FFFFh
Range
Units
0000h to FFFFh
Save
Parameter
Impossible
Parameter error
list
Save
Parameter
Impossible
Parameter error
list
Save
Parameter
Impossible

Advertisement