Parameter Error List (Obj. 2A45H)]; [Parameter Error List (Obj. 2A45H: 00H)]; [Parameter Error List 1 (Obj. 2A45H: 01H)] - [Parameter Error List 254 (Obj. 2A45H: Feh)]; Reset Alarm (Obj. 2A46H)] - Mitsubishi Electric MELSERVO JET Series User Manual

Ac servo system
Table of Contents

Advertisement

6.6

[Parameter error list (Obj. 2A45h)]

[Parameter error list (Obj. 2A45h: 00h)]

Data Type
Access
U8
RO
Description
The total number of Sub Indexes (= 254) is returned.
[Parameter error list 1 (Obj. 2A45h: 01h)] - [Parameter error list
254 (Obj. 2A45h: FEh)]
Data Type
Access
U16
RO
Description
During [AL. 037 Parameter error] occurrence, a list of servo parameter numbers that caused the alarm is returned.
The descriptions of [Parameter error list 1 (Obj. 2A45h: 01h)] to [Parameter error list 254 (Obj. 2A45h: FEh)] are as follows.
For example, if [Pr. PC01] is the cause of the error, "0201h" is returned.
When no error has occurred, "0000h" is returned.
Bit
Description
0 to 7
Servo parameter number
8 to 15
Servo parameter group number
00h: [Pr. PA _ _ ]
01h: [Pr. PB _ _ ]
02h: [Pr. PC _ _ ]
03h: [Pr. PD _ _ ]
04h: [Pr. PE _ _ ]
05h: [Pr. PF _ _ ]
0Ch: [Pr. PT _ _ ]
0Eh: [Pr. PN _ _ ]
11h: [Pr. PV _ _ ]
6.7

[Reset alarm (Obj. 2A46h)]

[Reset alarm (Obj. 2A46h: 00h)]

Data Type
Access
U16
RW
Description
The alarm that has occurred in the servo amplifier is cleared.
Writing "1EA5h" resets an alarm. Any value other than "1EA5h" is invalid.
When the object is read, "0000h" is returned.
6 Alarm Objects
44
6.6 [Parameter error list (Obj. 2A45h)]
Mapping
Default
Impossible
254
Mapping
Default
Impossible
0000h
Mapping
Default
Impossible
0000h
Range
Units
254 (fixed)
Range
Units
0000h to FFFFh
Range
Units
0000h to FFFFh
Save
Parameter
Impossible
Parameter error
list
Save
Parameter
Impossible
Parameter error
list
Save
Parameter
Impossible

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-jet-g seriesMelservo mr-jet-10g

Table of Contents