120: Comp - Multitap Delay; 121: Limiter - P4Eq; 122: Limiter - Chorus/Flanger - Korg KRONOS SGX-2 Parameter Manual

Table of Contents

Advertisement

120: Comp - Multitap Delay

This effect combines a mono compressor and a multitap
delay. You can change the order of the effects.
Wet: Mono In - Mono Out / Dry: Stereo In - Stereo Out
Left
Compressor
EQ Trim
LEQ HEQ
+
Comp
Output Level
Right
Envelope - Control
Routing
Routing
[Comp > Mt.Delay, Mt.Delay > Comp]
Switches the order of the compressor and multitap delay.

121: Limiter - P4EQ

This effect combines a mono limiter and a four-band
parametric equalizer. You can change the order of the
effects.
Wet: Mono In - Mono Out / Dry: Stereo In - Stereo Out
Left
Limiter
+
Limiter
Gain Adjust
Right
Envelope - Control
Routing
Routing
[Limiter > P4EQ, P4EQ > Limiter]
Switches the order of the limiter and parametric EQ.

122: Limiter - Chorus/Flanger

This effect combines a mono limiter and a chorus/flanger.
You can change the order of the effects.
Wet: Mono In - Stereo Out / Dry: Stereo In - Stereo Out
Left
Routing
Limiter
+
Limiter
EQ Trim
LEQ HEQ
Gain Adjust
Right
Envelope - Control
Routing
Wet / Dry
Multitap Delay
Feedback
Delay
(2)
(1)
High Damp
Mt.Dly Wet / Dry
Wet / Dry
Wet / Dry
Routing
Parametric 4Band EQ
Trim
Wet / Dry
Wet / Dry
Chorus/Flanger
Chorus/Flanger
Normal
+
Output Mode
Wet Invert
Feedback
Cho/Flng Wet / Dry
Wet / Dry
LFO: Tri / Sine
Mono-Mono Serial 120: Comp - Multitap Delay
Pre EQ
For detailed information, see "Pre EQ" on page 1003.
COMPRESSOR
For detailed information, see "COMPRESSOR" on
page 1002.
MULTITAP DELAY
This is a 2-tap delay. For detailed information, see
"MULTITAP DELAY" on page 1002.
OUTPUT
This is the standard effects output section, with modulatable
control over wet/dry balance. For more information, see
"OUTPUT" on page 904.
LIMITER
For detailed information, see "LIMITER" on page 1002.
PARAMETRIC EQ
This is a 4-band parametric EQ. For detailed information,
see "PARAMETRIC EQ" on page 1002.
OUTPUT
This is the standard effects output section, with modulatable
control over wet/dry balance. For more information, see
"OUTPUT" on page 904.
Routing
Routing
[Limiter > Flanger, Flanger > Limiter]
Switches the order of the limiter and chorus/flanger.
When Routing is set to Flanger > Limiter, the
Chorus/Flanger's Output Mode will be grayed out and
internally set to Normal.
LIMITER
For detailed information, see "LIMITER" on page 1002.
1009

Advertisement

Table of Contents
loading

Table of Contents