• 4100-3110 IDNet 2+2 Card
• 4100-5101 , 4100-5103 Expansion Power Supply NACs (including TrueAlert Non-Addressable SmartSync appliances)
• 4100-5111 , 4100-5113 System Power Supply NACs (including TrueAlert Non-Addressable SmartSync appliances)
• 4100-5125 , 4100-5127 Remote Power Supply NACs (including TrueAlert Non-Addressable SmartSync appliances)
• 4100-5120, , 4100-5122 TrueAlert Power Supply NACs
• 4100-1214 to 4100-1225, 4100-1228, 4100-1229, 4100-1230, 4100-1231, 4100-1232, 4100-1233, 4100-1234, 4100-1235, 4100-1236,
4100-1237, 4100-1238, 4100-1239, 4100-1314, 4100-1315, 4100-1316, 4100-1317, 4100-1318, 4100-1319, 4100-1320, 4100-1321,
4100-1322, 4100-1323, 4100-1324 4100-1325, 4100-1328, 4100-1329, 4100-1330, 4100-1331, 4100-1332, 4100-1333, 4100-1334,
4100-1335, 4100-1336, 4100-1337, 4100-1338, 4100-1339 100W Amplifier NACs
• 4100-1212, 4100-1213, 4100-1226, 4100-1227, 4100-1312, 4100-1313, 4100-1326, 4100-1327 Flex 50 Amplifier NACs.
• 4009-9401 TrueAlert Addressable Controller
• 4100-1270 Phone Controller and 4100-1272 4100-1273 Phone NAC cards
• 4009-9201 4009-9301 IDNet NAC Extender
• 4100-5116 Expansion Signal Card
• 4100-5401 ES-PS (Power Supply)
4100-5402 ES-XPS (Expansion Power Supply)
4100-5403 (Backup harness for the ES-PS. No supply.)
4100-5450 NAC Card (743-2254)
4100-5451 IDNAC Card (743-2253)
• 4100-6077 MX Digital Loop Card
• 4100-6311 ESMX Loop Card
• 4100-6312 ESMX Option Loop Card
• Local Mode is NOT supported by, but can co-exist with, the following:
• 4100 Legacy cards
• 4100-3101, 4100-3102, 4100-3103 Auxiliary Relay cards
• 4100-6048 VESDA Interface Kit
• 4100-6043 4100-6044 RS-232/2120 Interfaces
• 4100-1280 to 1287 LED/Switch Annunciators
• 4100-1290 24-Point Graphic I/O Module
• 4602-9101 SCU/ 4602-9102 RCU
• 4603-9101 LCD Annunciator
• 4100-1210 4100-1211, 4100-1311, 4100-1411 Audio Controller Board
• 4100-6014 Network Interface Card
• 4100-6052 DACT
• 4100-3115 XA Loop Interface Card
• 4100-6065 BMUX COMMs Module
• 4100-6066 TFX Loop Interface
Bear in mind the following limitations when local mode is in effect:
• If an alarm is already activated when local mode is initiated, the alarm remains activated in local mode.
• Software zones are not supported. Basic TrueAlert channels are supported.
• Alarm verification is not supported. All alarms are reported immediately.
• SMPL is not supported.
• TrueAlarm sensors have fixed thresholds.
6.1.8
LEDs
The TICs have the following LEDs:
page 66
4100ES Fire Alarm System Installation Guide
574-848
Rev. BQ