System Start-Up; Memory Module; Memory Module Overview - Danfoss VLT FC 280 Operating Manual

Midi drive with functional safety over fieldbus
Hide thumbs Also See for VLT FC 280:
Table of Contents

Advertisement

VLT® Midi Drive FC 280
Operating Guide
4.
Press [Off]. Note any deceleration problems.

5.8 System Start-up

The procedure in this section requires user-wiring and application programming to be completed. The following procedure is rec-
ommended after application set-up is completed.
Procedure
1.
Press [Auto On].
2.
Apply an external run command.
3.
Adjust the speed reference throughout the speed range.
4.
Remove the external run command.
5.
Check the sound and vibration levels of the motor to ensure that the system is working as intended.
If warnings or alarms occur, see

5.9 Memory Module

5.9.1 Memory Module Overview

The VLT® Memory Module MCM is a small memory device containing data such as:
Firmware for the drive (not including the firmware for communication on the control card).
PUD file.
SIVP file.
Parameter file.
The VLT® Memory Module MCM is an accessory. The drive comes without the memory module installed from the factory. A new
memory module can be ordered using the following ordering numbers.
Table 19: Ordering Number
Description
VLT® Memory Module MCM 102
VLT® Memory Module MCM 103
Each memory module has a unique serial number which cannot be modified.
The VLT® Memory Module MCM can be used on the drive together with firmware 1.5 and above.
The VLT® Memory Module MCM does not support copying functional safety related firmware and parameters.
Select correct options for parameter 31-40 Memory Module Function before configuring with the memory module.
Table 20: Description of Parameter 31-40 Memory Module Function
Parameter 31-40 Memory Module
Function
[0] Disabled
*[1] Only Allow Download
[2] Only Allow Upload
[3] Allow Both Download and Upload
50 | Danfoss A/S © 2022.02
8.2 Warning and Alarm Types
N O T I C E
N O T I C E
Description
Downloading or uploading data function is disabled.
Only allow downloading data from the memory module to the drive. This is the default
setting of parameter 31-40 Memory Module Function.
Only allow uploading data from the drive to the memory module.
If this option is selected, the drive downloads data from memory module first, and then
uploads data from the drive to the memory module.
for resetting the drive after a trip.
Ordering number
132B0359
132B0466
AQ381425076031en-000101 / 130R1223