Danfoss VLT FC 280 Operating Manual page 99

Midi drive with functional safety over fieldbus
Hide thumbs Also See for VLT FC 280:
Table of Contents

Advertisement

VLT® Midi Drive FC 280
Operating Guide
Parameter
Option/range
Parameter 42-85
[0] STO
Active Safe Func.
[9] SS1-t
[10] None
Parameter 42-86
Safe Option Info
Parameter 42-88
0.00-99.99
Supported Cus-
tomization File
Version
Parameter 42-89
0.00-99.99
Customization File
Version
0-65535
Parameter 600-44
Fault Message
Counter
Parameter 600-47
0-65535
Fault Number
Parameter 600-52
0-65535
Fault Situation
Counter
Table 48: Status Word 1
Bit
Name
0
Normal up
1
PUST
2
STO active
3
SS1-t active
4–7
Reserved
8
Safe output status
Danfoss A/S © 2022.02
Default
Usage
[10] None
Show the currently active safety function. Use param-
eter 0-20 Display Line 1.1 Small to parameter 0-22 Dis-
play Line 1.3 Small to show the function on the LCP.
0
Show the information about the safety option. Use
parameter 0-23 Display Line 2 Large and parameter
0-24 Display Line 3 Large to show the function on the
LCP large display line.
2.00
Show the maximum supported configuration file ver-
sion.
0.00 means the maximum version supported by the
safe system (the drive with the safety option).
1.00 means the maximum version supported by the
safety option.
2.00 means the maximum version supported by the
control card.
2.00
Show the currently used customization file version.
0
Is incremented each time that the fault buffer
changes.
0
Contain the internal fault number for each fault mes-
sage.
0
Sum of all of the fault situations since the last reset.
Description
0: Safety function, fail safe reaction is active or pending or warning is active.
1: Normal operation.
0: SFBC is not in PUST state.
1: SFBC in PUST state.
0: STO is not active.
1: STO is active.
0: SS1-t is not active.
1: SS1-t is active.
The safe output status of SFBC (from SFBC to PU).
0: Safe output deactivated.
1: Safe output activated.
Safety Functions
Con-
ver-
sion
index
0
-2
-2
AQ381425076031en-000101 / 130R1223 | 99
Data
type
u_int8
Visible
String
u_int16
u_int16
u_int16
u_int16
u_int16

Advertisement

Table of Contents
loading

Table of Contents