VLT® Midi Drive FC 280
Operating Guide
Table 53: Speed Up/Speed Down
FC
+24 V
12
+24 V
13
D IN
18
D IN
27
D IN
32
33
D IN
+10 V
50
A IN
53
COM
55
Speed
Reference
Start (18)
Freeze ref (27)
Speed up (32)
Speed down (33)
Illustration 48: Speed Up/Speed Down
7.2.3 Start/Stop
Table 54: Start/Stop with Reversing and 4 Preset Speeds
FC
+24 V
12
+24 V
13
D IN
18
D IN
27
D IN
32
33
D IN
+10 V
50
A IN
53
COM
55
104 | Danfoss A/S © 2022.02
Parameters
Function
Parameter 5-10 Terminal 18 Digital Input
Parameter 5-14 Terminal 32 Digital Input
Parameter 5-15 Terminal 33 Digital Input
*=Default value
Notes/comments:
Parameters
Function
Parameter 5-10 Terminal 18 Digital Input
Parameter 5-12 Terminal 27 Digital Input
Parameter 5-14 Terminal 32 Digital Input
Parameter 5-15 Terminal 33 Digital Input
Application Examples
Setting
*[8] Start
[19] Freeze Reference
[22] Speed Down
Setting
[8] Start
[10] Reversing
[16] Preset ref bit 0
[17] Preset ref bit 1
AQ381425076031en-000101 / 130R1223