VLT® Midi Drive FC 280
Operating Guide
Message
0 RPM
0.00A
!1(1)
SO Data Confirmation
Are you sure that you want
to overwrite the safety
parameters including the
level 1 password?
0 RPM
0.00A
!1(1)
SO Data Confirmation
Press [OK] to confirm
(commissioning test must be
performed) or [CANCEL] to
abort
Status
!1(1)
0 RPM
None
0.00KW
SO Custom. completed
SO RESET required!
!Safe Stop [W68]
Off Remote SO Req.RESET
Status
!1(1)
0 RPM
None
0.00KW
SO Custom. aborted
SO RESET required!
!Safe Stop [W68]
Off Remote SO Req.RESET
Table 41: Mismatch Between Safety Parameters in the Safety Option and in the Drive
Message
0 RPM
0.00 A
!1(1)
SO Param. Selection
Mismatch of SO param.set
detected. Please choose:
SO : Test1234_ 1.00
VLT : SafeSet1_ 1.00
Status
!1(1)
0 RPM
None
0.00KW
SO Custom. completed
SO RESET required!
!Safe Stop [W68]
Off Remote SO Req.RESET
86 | Danfoss A/S © 2022.02
Description
Decision box for continuing overwriting the existing data or to abort the procedure.
Press [OK] to complete the customization of the safety option. A reset is required to finalize this
procedure.
Press [Cancel] to abort the customization of the safety option. A reset is required to finalize this
procedure.
Description
Whenever there is a mismatch of safety parameters within the safety option and the drive, this
selection form is shown on the LCP. Select between the Safety data on safe option or the Safety
data on drive valid data.
If selecting [SO:...], the customization of the safety option is completed and a reset is required
to finalize this procedure.
Safety Functions
AQ381425076031en-000101 / 130R1223