VLT® Midi Drive FC 280
Operating Guide
ELECTRICAL HAZARD
Even after pressing the [Off/Reset] key, voltage is present at the terminals of the drive. Pressing the [Off/Reset] key does not dis-
connect the drive from mains. Touching live parts can result in death or serious injury.
-
Do not touch any live parts.
5.3.3 The Right-key Function on NLCP
Press [▹] to edit any of the 4 digits on the display individually. When pressing [▹] once, the cursor moves to the first digit and the
digit starts flashing as shown in
digits or move the decimal point.
Setup 1
Setup 1
Setup 1
Setup 1
Setup 1
Illustration 24: Right-key Function
[▹] can also be used for moving between parameter groups. When in Main Menu, press [▹] to move to the first parameter in the next
parameter group (for example, move from parameter 0-03 Regional Settings [0] International to parameter 1-00 Configuration
Mode [0] Open loop).
5.3.4 Quick Menu on NLCP
5.3.4.1 Operating Quick Menu
The Quick Menu gives easy access to the most frequently used parameters.
Procedure
1.
To enter Quick Menu, press [Menu] until the indicator in display is placed above Quick Menu.
38 | Danfoss A/S © 2022.02
W A R N I N G
Illustration
24. Press the [▵] [▿] to change the value. Pressing [▹] does not change the value of the
Commissioning
AQ381425076031en-000101 / 130R1223