Replacement Procedures; Accessor Assembly Removal - IBM System Storage TS3400 Tape Library Maintenance Information

Machine type 3577
Hide thumbs Also See for System Storage TS3400 Tape Library:
Table of Contents

Advertisement

Figure 9-28. Accessor assembly removal

Replacement Procedures

1. Remove the packaging from the replacement Accessor assembly.
2. To replace the Accessor assembly, perform the steps to remove the Accessor
3. Run the Library Verify test in the Service Mode menu. See "Running Library
4. If requested, take the library online. See "Taking the Library Offline/Online" on
5. Package the failed Accessor assembly in the same packaging that the new
6. Go to "End of Call" on page 7-26.
assembly in reverse order, taking the following points into account.
• Ensure that the flat cable lays flat along the flat cable plate.
• The flat cable passes underneath the flange on the Accessor assembly.
• After reconnecting the Accessor flat cable connector block, pull on the flat
cable to remove any slack and to ensure the cable lies flat along the entire
length of the flat cable plate.
Verify Diagnostics" on page 7-5.
page 7-23.
Accessor assembly was shipped to you in, and return to IBM.
2
Chapter 9. Check, Adjust, Remove, and Replace Procedures
1
9-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

L5u

Table of Contents