Prompting for Srce File for Operation on rmt3 located at 00-05-01-30
Please enter the following fields...
Enter Filename:
F1=Help
F5=Reset
11. While the microcode load takes place, the display shows:
"Operation running, please standby"
The drive display shows the loading status messages at the bottom of the display.
12. When the microcode load completes, the initiator display shows:
Operation completed successfully!
The drive performs a soft power-on reset (restart the microcode).
13. Press F10 to exit the microcode load.
14. Repeat the previous steps for each drive, then return here to complete this
procedure.
15. Press q to quit tapeutil.
16. Vary the device online to the host.
17. Remove the CD-ROM from the CD-ROM drive.
Note: You must have administrator privileges to perform the following step.
18. Update the VPD data in the host pSeries (RS/6000) AIX by unconfiguring the
device (Example: rmdev -l rmt3) and reconfiguring the device (Example: mkdev
-l rmt3).
Updating Microcode from Linux using TAPEUTIL
You may require assistance from the customer during this process.
1. At the drive service panel, verify that the drive is Online.
2. Verify that the drive is unloaded.
3. Verify that the drive is not in use by another host.
4. Start the tape utility program by typing IBMtapeutil at the prompt.
IBMtapeutil for Linux
==============================
1. Tape
2. Changer
3. Quit
==============================
Enter your choice:
F2=Refresh
F3=Cancel
F7=Commit
F10=Exit