IBM System Storage TS3400 Tape Library Maintenance Information page 22

Machine type 3577
Hide thumbs Also See for System Storage TS3400 Tape Library:
Table of Contents

Advertisement

Table 1-1. Library error codes (continued)
Code (H)
Description
At power-on initialization,
0001
a firmware error was
detected.
At power-on initialization,
0002
a RAM (base area) error
was detected.
At power-on initialization,
0003
a RAM (buffer area) error
was detected.
A usable drive could not
0008
be detected.
Information acquisition
0010
from the DHCP server
failed.
Time acquisition from the
0011
NTP server failed.
Library Drive Interface
(LDI) error during SCSI
command response.
0020
Transmit data abnormality
detected (NAK reception).
Library Drive Interface
(LDI) error during SCSI
command response.
0021
Receive timeout detected
(ACK/NAK reception).
Library Drive Interface
(LDI) error during SCSI
0022
command response.
Drive offline detected.
Library Drive Interface
(LDI) error during SCSI
0023
command response.
Drive busy detected.
Library Drive Interface
(LDI) error during SCSI
command response.
0024
Drive abnormality
detected.
1-6
TS3400 Tape Library Maintenance Information
Panel
Indication
1. Cycle the power and try again.
Error LED
2. Replace the Library Control Blade (page 9-8).
ON and
3. Confirm/Replace the power supply units (page 9-7).
Alarm LED
4. Replace the Back Board assembly (page 9-37).
ON
5. Replace the TS3400 Tape Library chassis (page 9-44).
Error LED
1. Cycle the power and try again.
ON and
2. Replace the Library Control Blade (page 9-8).
Alarm LED
3. Confirm/Replace the power supply units (page 9-7).
OFF
4. Replace the Back Board assembly (page 9-37).
5. Replace the TS3400 Tape Library chassis (page 9-44).
CHK 0003
1. Confirm the drive connection.
2. Cycle the power and try again.
3. Replace the Library Control Blade (page 9-8).
CHK 0008
4. Replace the drive canister (page 9-11).
5. Replace the Drive Docking Card (page 9-19).
6. Replace the Back Board assembly (page 9-37).
7. Replace the TS3400 Tape Library chassis (page 9-44).
None
1. Confirm the server settings.
(Error code
2. Confirm the LAN cable connection.
appears in
3. Cycle the power and try again.
library log.)
4. Replace the Library Control Blade (page 9-8).
5. Replace the TS3400 Tape Library chassis (page 9-44).
1. Confirm the drive connection.
2. Cycle the power and try again.
3. Replace the Library Control Blade (page 9-8).
4. Replace the drive canister (page 9-11).
5. Replace the Drive Docking Card (page 9-19).
6. Replace the Back Board assembly (page 9-37).
7. Replace the TS3400 Tape Library chassis (page 9-44).
None
(Error code
appears in
library log.)
Action Required

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the System Storage TS3400 Tape Library and is the answer not in the manual?