ESAB PUA 1 Manual page 36

Table of Contents

Advertisement

4.4.2
Weld Data Settings
Use the settings menu to set the values of the various welding parameters.
We will make the following settings:
CURRENT = 200 A
S
SLOPE--UP TIME = 2.0 s
S
SLOPE--DOWN TIME = 1.4 s
S
GAS PRE--FLOW = 3.0 s
S
GAS POST--FLOW = 5.0 s
S
Press the MENU key, call up the settings menu by pressing the SETUP button.
Current
Position the cursor
on the line for
CURRENT.
Use one of the
plus/minus buttons
to set the value to
200 A.
Slope- - up and Slope- -down
The slope--up and slope--down parameters are each connected to a plus/minus
button. The upper key is used for setting of slope--up, and the lower button is used
for setting of slope--down.
Place the cursor on
the row for SLOPE
UP and SLOPE
DOWN TIME. Set
SLOPE UP TIME
to 2.0 s. by
stepping with the
upper plus/minus
button.
bu12d04a
WELD DATA SETTING
CURRENT:
SLOPE UP TIME:
SLOPE DOWN TIME:
GASPREFLOW:
GASPOSTFLOW:
GAS
4
PURGE
STROKE
WELD DATA SETTING
CURRENT:
SLOPE UP TIME:
SLOPE DOWN TIME:
GAS PRE--FLOW:
GAS POST--FLOW:
GAS
4
PURGE
STROKE
- - 36 - -
200 A
4.0 s
6.0 s
2.5 s
3.3 s
QUIT
200 A
# 2.0 s
6.0 s
*
2.5 s
3.3 s
QUIT