ESAB PUA 1 Manual page 22

Table of Contents

Advertisement

Creep Start
Here you simply choose whether you want to use the creep start function or not, i.e.
YES or NO. Wire feed speed and creep start are pre--set and cannot be changed.
Position the cursor
on the line CREEP
START. Press
enter to call up a
list of options.Set it
to YES.
Hot Start
To begin with, choose whether or not you want to use the hot start function. If you
decide to use the hot start function, you should then enter the hot start time and any
increase in the wire feed speed.
Position the cursor
on the line HOT
START. Press
enter to call up a
list of options.Set it
to YES.
Position the cursor
on the line HOT
START TIME. Set
it to 1.0 s using one
of the plus/minus
buttons.
bu12d04a
START DATA. SYNERGIC MODE
GASPREFLOW:
CREEPSTART:
HOT START:
CRATER
HOT
FILL
START
START DATA. SYNERGIC MODE
GASPREFLOW:
CREEPSTART:
HOT START:
HOT START TIME:
WIRE SPEED:
CRATER
HOT
FILL
START
START DATA. SYNERGIC MODE
GASPREFLOW:
CREEPSTART:
HOTSTART:
HOT START TIME:
WIRE SPEED:
CRATER
HOT
FILL
START
- - 22 - -
0.8 s
YES
YES
4- -
STROKE
QUIT
0.8 s
YES
YES
1.0s
51 in/min
4- -
D
STROKE
QUIT
0.8 s
YES
YES
1.0 s
51 in/min
4- -
D
STROKE
QUIT
ENTER
ENTER

Advertisement

Table of Contents
loading

Table of Contents