10
APPENDIX
10.1
Setting Ranges and Setting Steps
MIG
Parameter
Wire feed speed
Voltage
Inductance
Pulse current
Pulse time
Pulse frequency
Background current
Slope time
Ka
Ki
Gas pre--flow time
Gas post--flow time
Burnback time
Hot start time
Wire feed speed. Hot start
Voltage increase. Hot start
Crater fill time
Final wire feed speed. Crater fill
Final voltage. Crater fill
Shake- -off pulse
Regulator type
Italicised parameters are not available in synergetic mode.
The parameter regulator type does not have a true setting range. In MIG welding it
is possible to choose between twelve different regulator types numbered 1--12.
STICK
Parameter
Weld current
Arc pressure
Italicised parameters are not available in synergetic mode.
bu12d04a
Setting range
59--984 in/min
8.0--60.0 V
0--100%
100--600 A
1.7 -- 25.5 ms
20 -- 312 Hz
12--300 A
1--9
0--100%
0--100%
0.0--25.0 s
0.0--25.0 s
0.00--1.00 s
0.0--10.0 s
0.0--787 in/min
0.0--60.0 V
0.0--10.0 s
59--635 in/min
8.0--60 V
10--120%
Type number 1--12
Setting range
16--320 A (Aristo 320)
16--450 A (Aristo 450)
0--100%
- - 78 - -
Setting step
4 in/min
0.25 V
1%
4 A
0.1 ms
2 Hz
4 A
1
1%
1%
0.1 s
0.1 s
0.01 s
0.1 s
4 in/min
0.25 V
0.1 s
4 in/min
0.25 V
1%
--
Setting step
1 A
1 A
1%