2.8.3
Start Data Settings
Using the start data menu you can adjust the settings that affect the starting
sequence during MIG welding. We will set the following:
GAS PRE--FLOW = 0.8 s
S
CREEP START = YES
S
HOT START = YES
S
HOT START time = 1.0 s
S
HOT START wire feed speed = 98 in/min (2.5 m/min).
S
We begin by pressing the MENU button to display the main menu.
Press the SET button to view the settings menu.
Position the cursor
on the line START
DATA and press
ENTER.
Gas Pre- - Flow Time
Here you enter the length of time you want the shielding gas to flow before welding
begins.
Position the cursor
on the line for GAS
PREFLOW. Set it
to 0.8 s using one
of the plus/minus
buttons.
bu12d04a