ESAB PUA 1 Manual page 20

Table of Contents

Advertisement

The next line in the main menu is AUXILIARY FUNCTIONS (OPTIONS). You can
read more about these functions in the section "AUXILIARY FUNCTIONS" under
section 9.
2.8.2
Weld Data Settings
From the settings menu, you can set values for various welding parameters, such as
voltage and wire feed speed. By activating the synergic function, many of these
settings will be handled by a microprocessor.
We begin by pressing the MENU button to display the main menu. Press the SET
button to view the settings menu. We'll now make the following settings:
WIRE FEED SPEED = 393 in/min (10.0 m/min).
S
Wire Feed Speed
Position the cursor
on the line
WIRE SPEED.
Set it to 393 in/min
(10.0 m/min) using:
In the settings menu you can now also see the values that the microprocessor has
chosen for voltage and inductance.
The voltage parameter may also be adjusted if required.
bu12d04a
PROCESS:
METHOD:
WIRE TYPE:
SHIELDING GAS:
WIRE DIAMETER :
AUXILIARY FUNCTIONS
SET
MEASURE
VOLTAGE:
WIRE SPEED:
INDUCTANCE:
SYNERGIC MODE
START DATA . . .
STOP DATA . . . .
CRATR
HOT
FILL
START
- - 20 - -
ESAB LUD 450
MIG
DIP/SPRAY
Metal cored Fe
Ar+8%CO2
0.040" (1.0mm)
"
FAST
MEMORY
MODE
WELD PARAMETERS
# 29.0 (+0.0) V
393 in/min (10.0 m/min)
*
80 %
ON
4- -
STROKE
QUIT
ENTER