BASE REMOVAL
•
After having removed the filter housing
cover, proceed with removing the air
filter retainer by lifting it.
•
Remove the air filter.
•
Disconnect the main wiring harness
and the canister system valve from the
cable gland on the filter housing base.
•
Operating on the left side of the vehi-
cle, remove the screw that fastens the
front bank oil pressure sensor to the
base of the filter housing, removing al-
so the gear sensor connector support
bracket.