APRILIA Tuono V4 1100 Factory Service Station Manual page 173

Table of Contents

Advertisement

Tuono V4 1100 Factory
P1606 Hardware and software incompatibility
Error cause
Incorrect engine control unit mapping
The presence of this error is signalled by the fixed lighting of the general warning light.
Troubleshooting
Call the Help Desk
NOTE
THIS ERROR DETERMINES THE ENGINE STOP AN THE DEACTIVATION OF THE STARTER MO-
TOR.
P1607 Saved data file (for safety reasons)
Electrical diagnostic:
Filled
Error cause
This indication appears only if the Level 2 safety has reset the engine (C gravity).
The instrument cluster does not indicate the presence of this error even in the ATT status
Troubleshooting
Perform the troubleshooting for the other detected errors.
P1608 a-PRC (Aprilia Performance Ride Control) operating error
Electrical diagnostic:
Incorrect a-PRC scheduling / Incorrect CheckSum of the software on Flash / Control unit
voltage too low for a-PRC controls
Error cause
Due to the fact that the safety system detected a serious fault, the control unit has disabled
the a-PRC system.
The instrument cluster indicates the presence of this error with the MI warning light on fixed.
Troubleshooting
Contact technical service.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1650 Engine events configuration Checksum calculation error
Error cause:
Corrupt Flash-eeprom (hardware problem).
Upload (e.g. in service) of an incompatible software version, therefore missing the reference
check-sum.
The presence of this error is signalled by the fixed lighting of the general warning light.
Troubleshooting:
Electrical system
ELE SYS - 173