Tuono V4 1100 Factory
P1606 Hardware and software incompatibility
Error cause
•
Incorrect engine control unit mapping
The presence of this error is signalled by the fixed lighting of the general warning light.
Troubleshooting
•
Call the Help Desk
NOTE
THIS ERROR DETERMINES THE ENGINE STOP AN THE DEACTIVATION OF THE STARTER MO-
TOR.
P1607 Saved data file (for safety reasons)
Electrical diagnostic:
•
Filled
Error cause
•
This indication appears only if the Level 2 safety has reset the engine (C gravity).
The instrument cluster does not indicate the presence of this error even in the ATT status
Troubleshooting
•
Perform the troubleshooting for the other detected errors.
P1608 a-PRC (Aprilia Performance Ride Control) operating error
Electrical diagnostic:
•
Incorrect a-PRC scheduling / Incorrect CheckSum of the software on Flash / Control unit
voltage too low for a-PRC controls
Error cause
•
Due to the fact that the safety system detected a serious fault, the control unit has disabled
the a-PRC system.
The instrument cluster indicates the presence of this error with the MI warning light on fixed.
Troubleshooting
•
Contact technical service.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1650 Engine events configuration Checksum calculation error
Error cause:
•
Corrupt Flash-eeprom (hardware problem).
•
Upload (e.g. in service) of an incompatible software version, therefore missing the reference
check-sum.
The presence of this error is signalled by the fixed lighting of the general warning light.
Troubleshooting:
Electrical system
ELE SYS - 173