APRILIA Tuono V4 1100 Factory Service Station Manual page 249

Table of Contents

Advertisement

Tuono V4 1100 Factory
Pin 4: supply (brown)
DIAGNOSTIC TOOL: ELECTRICAL ERRORS
-
DIAGNOSTIC TOOL: LOGIC ERRORS
P1901 Ax acceleration sensor plausibility
Functional diagnosis:
Faulty sensor/Signal not valid
Troubleshooting:
With faulty sensor, the component inside the control unit is damaged and replacement of the control
unit is recommended. With signal not valid, the sensor has generated a signal out of range that is still
sent to the injection control unit together with the relevant error.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1902 Az acceleration sensor plausibility
Functional diagnosis:
Faulty sensor/Signal not valid
Troubleshooting:
With faulty sensor, the component inside the control unit is damaged and replacement of the control
unit is recommended. With signal not valid, the sensor has generated a signal out of range that is still
sent to the injection control unit together with the relevant error.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1903 Yaw sensor plausibility
Functional diagnosis:
Faulty sensor/Signal not valid
Troubleshooting:
With faulty sensor, the component inside the control unit is damaged and replacement of the control
unit is recommended. With signal not valid, the sensor has generated a signal out of range that is still
sent to the injection control unit together with the relevant error.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1904 Roll sensor plausibility
Functional diagnosis:
Faulty sensor/Signal not valid
Troubleshooting:
Electrical system
ELE SYS - 249

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2q000504

Table of Contents