The NGI-S04C2 has a DIN rail bracket on the back of the Switch to satisfy the mounting
installation.
Location: The NGI-S04C2 can be DIN-Rail-mounted in cabinet or enclosure.
Mounting the Switch
Place the NGI-S04C2 on the DIN rail from above using the slot and push the front of the
switch toward the mounting surface until it snaps into place with a click sound.
Dismounting the Switch
1.
Push the switch down to free the bottom of the plate from the DIN rail.
2.
Rotate the bottom of the device towards you and away from the DIN rail.
3.
Once the bottom is clear of the DIN rail, lift the device straight up to unhook it from
the DIN rail..
Wall-Mount Installation
Location: The NGI-S04C2 can be placed on a horizontal surface through wall-mounted
kit
Place the switch by using mounting holes on the wall at the appropriate place
Ground the Switch: Before powering on the switch, ground the switch to earth.
Ensure the rack on which the switch is to be mounted is properly grounded and
incompliance with ETSI ETS 300 253. Verify that there is a good electrical connection to
the grounding point on the rack (no paint or isolating surface treatment).
Attention
This product is intended to be mounted to a well-grounded mounting surface
such as a metal panel.
Caution:
The earth connection must not be removed unless all power supply connection
has been disconnected.
Caution: